General rubber sheathed flexible cable
- Stable quality: implement process quality control, pay attention to quality, and test in many aspects!
- Reasonable price: effective internal cost control, cost reduction and customer service!
- Quick delivery: perfect production line, sufficient inventory and shortened delivery time!
- Tel:86-0550-2406812
- Mobile phone:17856844858
- E-mail:13605508812@139.com
Description
This product is suitable for household appliances, electric tools and various mobile electrical equipment with AC rated voltage of 1KV and below.
1. Production execution standards
JB8735.2-1998
Two, use characteristics
1. Rated voltage 1KV (YC) type
2. The long-term allowable working temperature of the core should not exceed 65℃
3. "W" type cable has weather resistance and certain oil resistance, and is suitable for use outdoors or where it is exposed to oil.
4. ZR type cable has flame retardant properties
3. Model, name and main purpose
Model Name Main Purpose
YQ, YQW light rubber sheathed flexible cable for light mobile electrical equipment and tools
YZ, YZW medium-sized rubber-sheathed flexible cables are used for various mobile electrical equipment and tools
YC, YCW heavy-duty rubber-sheathed flexible cables are used for various mobile electrical equipment and can withstand large mechanical external forces.
Fourth, the range of specifications
Model Rated voltage V Number of cores Nominal cross section mm2
YQ,YQW 300/300 2,3 0.3~0.5
YZ,YZW 300/500 2,3,4,5
3+1
6 4~6
1.5~6
0.75~6
YC 450/750
1
2
3,4
5
3+1
1.5~240
1.5~150
1.5~150
1.5~25
2.5~150
YCW 450/750
2
3
3+1
35~95
120~150
2.5~150
5. Specifications and technical parameters
①300/300V YQ, YQW light
Number of cores×nominal cross section (mm2) Conductive wire core Average outer diameter at 20℃ Conductor resistance≤(Ω/km) Reference weight
Number/wire diameter Lower limit Upper limit Copper core Tinned copper core YQ YQW
2×0.3 16/0.15 4.6 6.6 69.2 71.2 30 31.5
2×0.5 28/0.15 5.0 7.2 39.0 40.1 43 45.5
3×0.3 16/0.15 4.8 7.0 69.2 71.2 36 38.1
3×0.5 28/0.15 5.2 7.6 39.0 40.1 74 77.0
②300/500V YZ, YZW type
Nominal cross section (mm2) Conductive core 20℃ Conductor resistance≤(Ω/km) Cable outer diameter reference (mm)
Number/wire diameter mm 2 cores 3 cores 4 cores 5 cores (3+1) cores 6 cores
0.75 24/0.20 26.0 ˉ ˉ ˉ ˉ ˉ 10.7
1.0 32/0.20 19.5 ˉ ˉ ˉ ˉ ˉ 11.5
1.5 30/0.25 13.3 ˉ ˉ ˉ ˉ 11.2 14.0
2.5 49/0.25 1.98 ˉ ˉ ˉ ˉ 13.3 16.9
4 56/0.30 4.95 13.7 14.5 16.2 17.9 15.7 19.8
6 84/0.30 3.30 15.1 16.1 17.9 20.0 17.5 22.1
③450/750V YC heavy duty
Nominal cross section (mm2) Conductive core 20℃ Conductor resistance≤(Ω/km) Cable outer diameter reference (mm)
Number/wire diameter mm 1 core 2 cores 3 cores 4 cores 5 cores (3+1) cores
1.5 30/0.25 13.3 7.1 11.0 11.9 13.1 14.4 15.2
2.5 49/0.25 7.98 7.9 13.1 14.0 15.5 17.0 17.4
4 56/0.30 4.95 9.0 15.1 16.2 7.9 19.9 19.4
6 84/0.30 3.30 9.8 16.8 18.0 20.0 22.2 24.6
10 84/0.40 1.91 11.9 22.6 24.2 26.5 29.1 28.3
16 126/0.40 1.21 13.4 25.7 27.6 30.1 33.3 34.4
25 196/0.40 0.780 15.8 30.7 33.0 36.6 40.4 37.3
35 276/0.40 0.554 17.9 34.6 37.1 41.1 _ 44.7
50 396/0.40 0.386 20.6 40.1 42.9 47.5 _ 49.8
70 360/0.50 0.272 23.3 45.1 48.3 54.0 _ 55.1
95 475/0.50 0.206 26.0 51.0 54.0 61.0 _ 58.8
120 608/0.50 0.161 28.6 _ 60.0 66.0 _ 64.5
150 756/0.50 0.129 31.4 _ 66.0 73.0 _ _
185 925/0.50 0.106 34.4 _ _
_ _
240 1221/0.50 0.0801 38.3 _ _ _ _ _
300 1525/0.50 0.0641 41.9 _ _
_ _
400 2038/0.50 0.0486 46.8 _ _ _ _ _
④450/750V YCW heavy duty
Nominal cross section (mm2) Conductive core 20℃ Conductor resistance≤(Ω/km) Cable outer diameter reference (mm)
Number/wire diameter mm 2 cores 3 cores (3+1) cores
2.5 49/0.25 7.98 _ _ 15.2
4 56/0.30 4.95 _ _ 17.4
6 84/0.30 3.30 _ _ 19.4
10 84/0.40 1.91 _ _ 24.6
16 126/0.40 1.21 _ _ 28.3
25 196/0.40 0.780 _ _ 34.4
35 276/0.40 0.554 34.6 _ 37.3
50 396/0.40 0.386 40.1 _ 44.7
70 360/0.50 0.272 45.1 _ 49.8
95 475/0.50 0.206 51.0 60.0 55.1
120 608/0.50 0.161
66.0 58.8
150 756/0.50 0.129
64.5
Six, delivery length
1. The circle is 100M, and the coil should be greater than 100M;
2. The short cable length should not be less than 10M, the delivery quantity of the short cable length should not exceed 10% of the total length of delivery, and each package should not exceed five segments;
3. According to the agreement between the two parties, the delivery of cables of any length is allowed, and the length error is ±0.5%;
4. The user has requirements for flame retardant properties of the product, and a supplementary agreement is required in the contract